Two things determine whether a heating and cooling system is efficient in practice: the rating of the equipment, and whether it is the right size for the house. Of the two, sizing is the one more often got wrong and the one with the larger consequences.
What the ratings mean
SEER and SEER2 measure seasonal cooling efficiency – cooling output over a season divided by electricity used. Higher is better. SEER2 uses a revised test method with more realistic external static pressure, so SEER2 numbers run slightly lower than old SEER numbers for the same equipment. Compare like with like.
EER measures efficiency at a single high outdoor temperature, which matters in consistently hot climates.
HSPF and HSPF2 do the same job for heating with a heat pump.
COP is the instantaneous ratio of heat delivered to energy used, commonly quoted for heat pumps. A COP of 3 means three units of heat per unit of electricity.
AFUE rates combustion furnace and boiler efficiency as a percentage of fuel converted to useful heat.
Why oversizing is the common failure
An oversized air conditioner cools the air to the thermostat setpoint quickly and shuts off. That sounds good and is not. Short cycles mean:
- Poor dehumidification. Removing moisture takes run time. A unit that runs in short bursts leaves the house cold and clammy.
- Higher energy use. Start-up is the least efficient part of a cycle, and frequent starts raise consumption.
- Temperature swings and uneven comfort between rooms.
- Shorter equipment life from repeated compressor starts.
Undersizing is less common and more obvious – the system runs continuously and never reaches setpoint on extreme days.
How sizing should be done
Properly, by a room-by-room load calculation – in North America the Manual J method, elsewhere an equivalent heat loss and gain calculation. It accounts for floor area, insulation levels, window area and orientation, air leakage, ceiling height, local design temperatures, occupancy and internal gains.
Rules of thumb based on floor area alone are unreliable because two houses of the same size can differ by a factor of two in heat demand. If a contractor quotes a size from square footage without asking about insulation and windows, get another quote.
Crucially: do the insulation and air sealing work first, then size the system to the improved house. Sizing to the old house locks in oversized equipment for fifteen years.
Ductwork matters as much as the box
In ducted systems, leaky or poorly designed ducts routinely waste a substantial share of conditioned air, often into unconditioned lofts or crawl spaces. Duct sealing and insulation is frequently a better investment than a higher-SEER unit. The matching design calculation for duct sizing – Manual D in North America – is skipped more often than it is done.
Variable speed and staging
Single-stage equipment is either fully on or off. Two-stage runs at a lower output most of the time. Variable-speed inverter equipment modulates continuously, running long and low, which gives better humidity control, steadier temperatures and higher real-world efficiency. The premium is worth it in climates with long shoulder seasons.
What to check before buying
- Has a proper load calculation been done, with a written copy for you?
- Are the indoor and outdoor units a matched pair? A mismatched pair does not deliver the rated efficiency.
- Will the ductwork be inspected, sealed and sized, or reused as-is?
- Is the refrigerant charge to be weighed in and verified rather than estimated?
- What is the airflow target, and will it be measured on commissioning?
- Are there rebates or grants for higher-efficiency equipment in your area?
The honest summary
A correctly sized, well-installed mid-efficiency system will outperform a high-SEER system installed badly, every time. Specify the installation quality as carefully as you specify the rating.